The display of the revision index (revision label) on drawings and BOMs can be done with „1“, „a“, or „A“.
Configure the following parameters in the Settings (speedy Administrator):
[solidworks.revision.revlabel] and [session.revlabel]
value | Result |
1 | Default (1, 2, 3, …) |
2 | A, B, C, … |
3 | a, b, c, … |
In the file name of the documents always digits are always used
(e.g. „ET-000001[1].sldprt“)
The drawing header contains a certain number of revision entries.
A | Initial release | 07.22.2014 | M. Mustermann |
Rev. | Change | Date | Name |
To define the number, the following settings are necessary:
The parameter [solidworks.revision.first] determines whether the „zeroth“, i.e. very first version is suppressed.
Value | Result |
0 | very first version „0“ is not suppressed |
1 | very first version is suppressed. (should be the default setting) |
The SolidWorks file properties are:
If the components of an assembly are master parts and the option [solidworks.bomtable.basepartignore] is set, these parts will not be added to the BOM. If this affects all components of the assembly, the BOM is empty.
Remedy:
Deactivate the function [solidworks.bomtable.basepartignore].
If a PDF of the parts list is to be saved under the article upon release, the following parameters must be set via HeidiSQL in the table dm_setting table:
[document.release.bomfiletype.] = „.pdf“
Then a parts list in PDF format is created upon release.
With the paramater: [document.release.bomtype] can be controlled,
what kind of parts list is created:
0 := Standard BOM (assembly BOM)
1 := Summarised assembly parts list (e.g. interesting for welded parts)
2 := Summed parts lists
3 := Child component parts list
4 := Structure BOM
The weight is determined by SolidWorks in kilograms and thus taken over by speedy. However, if you want to display the weight in grams, the property format must be adapted.
To do this, go to the speedy administration to the property formats area and select the property format [WEIGHT].
The following values must be set:
Data type | Formula |
Default value | WEIGHT |
Default | FORMAT(„%0.2f“, ATOF(WEIGHT)*1000); |
The weight is displayed in the standard of speedy with a point as decimal separator.
This affects the title block and the parts list.
To change the decimal separator to a comma, the property format must be adapted.
To do this, go to the speedy administration to the property formats area and select the property format [WEIGHT].
The following values must be set:
Data type | Floating point number |
Format | %0.3f |
Change dot character | to comma |
When starting the speedy Explorer (dwWin7.exe) or the speedy Administrator (dwAdmin7.exe) via network, the following Windows security warning may occur:
Remedy: Adjust local group policy (Win 7).
The warning message will no longer appear when starting the programme in the future.
You can hide drives by making an entry in the registry database. These drives are then no longer displayed under „My Computer“ and in Explorer.
Start the registry editor and change the entries in the registry as described.
[HKEY_CURRENT_USER\Software\Microsoft\Windows\CurrentVersion\Policies\Explorer]
NoDrives (REG_DWORD) := 0x000000
Binary value per drive letter:
Drive | Value |
---|---|
A | 0x000001 |
B | 0x00000002 |
C | 0x00000004 |
D | 0x00000008 |
… |